Model
1322 |
|
Model
1308 |
|
Model
2503 |
|
Model
2507 |
|
| Vertical
Lift |
GPM |
Watts |
GPM |
Watts |
GPM |
Watts |
GPM |
Watts |
| 20
feet |
0.51 |
27 |
1.25 |
30 |
2.50 |
48 |
4.00 |
57 |
| 40 |
0.51 |
32 |
1.25 |
48 |
2.50 |
60 |
3.95 |
78 |
| 60 |
0.51 |
36 |
1.20 |
54 |
2.40 |
78 |
3.90 |
102 |
| 80 |
0.49 |
40 |
1.20 |
60 |
2.30 |
93 |
3.90 |
120 |
| 100 |
0.49 |
45 |
1.20 |
66 |
2.30 |
105 |
3.85 |
144 |
| 120 |
0.48 |
50 |
1.20 |
66 |
2.25 |
120 |
3.80 |
165 |
| 140 |
0.48 |
56 |
1.20 |
75 |
2.20 |
138 |
3.65 |
195 |
| 160 |
0.47 |
62 |
1.20 |
84 |
2.20 |
153 |
|
|
| 180 |
0.47 |
68 |
1.18 |
93 |
2.15 |
165 |
|
|
| 200 |
0.47 |
74 |
1.16 |
99 |
2.15 |
180 |
|
|
| 240 |
0.45 |
90 |
1.14 |
117 |
2.15 |
204 |
|
|
| 280 |
0.44 |
102 |
1.10 |
135 |
|
|
|
|
| 320 |
0.41 |
120 |
1.10 |
156 |
|
|
|
|
| 360 |
0.41 |
134 |
1.05 |
171 |
|
|
|
|
| 400 |
0.40 |
150 |
1.00 |
198 |
|
|
|
|
| 440 |
0.39 |
168 |
1.10 |
269 |
|
|
|
|
Note:
Calculated values in table measured at array direct voltage. A battery
powered setup will have 10% less flow and wattage.
*
For PV direct pumping, array watts must exceed pump watts by 20% or more.
A Current booster controller is also required.
**
To approximate gallons supplied per day, multiply the appropriate GPM figure
by 60, and then by the peak hours of insolation per day (in your area).

|